Focus On Water Division
Pay For Performance
Previously Awarded Site Summary

Intended for use by NDEE's pre-qualified Pay for Performance Contractors.

Potential bidding Contractors should not contact the State Contractor that performed the Tier 1 & 2 with questions about the site.

Those types of questions should be addressed to Phil Hargis at (402) 471-3150 or Email at Phil.Hargis@Nebraska.Gov.

Date: 6/5/03 
Site Name: Standing Elk Oil
UG# 120898-GW-1615
Address: 1 Mile West of Gordon on Hwy 20, South Side
County: Sheridan
Closest Town Gordon
Legal Description: NE1/4, NE1/4, Sec 35, T33N, R42W
Contractor Performing Assessment: Geotechnical Services Inc.
Tier 1 Date: 11/1/01 
Tier 2 Date: 11/2/02 
Property Owner’s Name: Jerry Fochtman
Property Owner’s Phone Number: Home, 308-282-0188 Cell, 308-360-0610
Contamination Types: Diesel & Gasoline
PFP Bid Number: NE-008
Posting Date: 2/14/03 
Closing Date for requesting clarifications from the NDEE: 8/8/03 
Clarifications to relevant qustions will be issued by the NDEE by: 8/13/03 
Bid Submittal Deadline 8/29/03 at 2:00 pm central time.
Site Summary:

Standing Elk Oil service station became a LUST site in late 1998 when one of the nine tanks located at the site failed a tightness test. All nine tanks were removed in December of 1998 and January of 1999. Standing Elk Oil is presently a cafe named the Western Cafe and is open for business. The site is located in the northwestern part of the State in an area described as the high plains region. The topography is described as flat-lying which lies above the Niobrara River valley. The materials of the plains are sandstone and clays. Ground water is approximately 37 feet deep in the area and the soils above the water table are mostly sand with some clay.
Table 1. Final Tier 2 Sampling Results:

All COC concentrations below are in parts per million (mg/l).


If a duplicate sample had higher concentrations during the final sampling, the higher number is listed.
Well
Benzene
Toluene
Ethyl-
benzene
Xylenes
MTBE
n-Hexane
Naphth-
alene
TEH-
Diesel
Total Conc.
MW-3**
FP
FP
FP
FP
FP
FP
FP
FP
FP
MW-4
2.820
1.180
.126
.827
ND
.031
.059
.477
5.520
MW-5
.267
.002
ND
.037
ND
.003
.013
ND
.322
MW-15
4.860
6.120
.983
5.470
.006
.125
.273
3.250
21.087
MW-16
13.100
22.200
1.500
7.340
ND
.526
.353
15.700
60.719
MW-17
1.610
7.400
.130
1.180
ND
.024
.075
1.330
11.749
Plume Initial Concentration
22.657
36.902
2.739
14.854
.006
.709
.773
20.757
99.397
Plume SSTL Concentration
1.891
4,950
603.500
5,590
11.293
4,730
649.990
5,191
21,727.674
Plume Initial Concentration above SSTLs
20.766
Not Above
Not Above
Not Above
Not Above
Not Above
Not Above
Not Above
Not Above
MW-1*
1.200
12.200
2.600
20.900
ND
ND
ND
ND
36.900
MW-2*
5.900
ND
ND
15.6
ND
ND
5.700
ND
27.200
MW-6*
ND
ND
ND
ND
ND
ND
ND
ND
ND
MW-7*
ND
ND
ND
ND
ND
ND
ND
ND
ND
MW-8*
ND
ND
ND
ND
ND
ND
ND
ND
ND
MW-11*
ND
ND
ND
ND
ND
ND
ND
ND
ND
MW-12*
ND
ND
ND
ND
ND
ND
ND
ND
ND
MW-13*
NS
NS
NS
NS
NS
NS
NS
NS
NS
MW-14*
ND
ND
ND
ND
ND
ND
ND
ND
ND
Numbers in red exceed the SSTLs
* These monitor wells are at or below detection limits or calculated SSTLs
** Monitor well #3 SSTLs are not included in the Plume SSTL concentrations for interim payments. The SSTLs will be used for final payment only. This well has intermittent free product.



Table 2. SSTLs:

Well

Benzene
Toluene
Ethylbenzene
Xylenes
MTBE
n-Hexane
Naphthalene
TEH-Diesel
MW-3
1.160
4,950
321
5,590
4.270
4,730
636
1,950
MW-4
.253
>Sol
63.300
>Sol
.945
>Sol
>Sol
438
MW-5
.109
>Sol
25.600
>Sol
.408
>Sol
13.900
190
MW-15
.771
>Sol
>Sol
>Sol
2.850
>Sol
>Sol
1,310
MW-16
.488
>Sol
126
>Sol
1.810
>Sol
>Sol
837
MW-17
.270
>Sol
67.600
>Sol
1.010
>Sol
>Sol
466

Monitor well #3 SSTLs will be used for final payment only.
Pictures:

(See attached file: Mvc-517f.pdf)
SizeFile Name
45 KB Mvc-517f.pdf
MAPS:
Area

(See attached file: Standing Elk.PDF)
SizeFile Name
142 KB Standing Elk.PDF
Benzene Contour

(See attached file: BENZENE.PDF)
Site Specifications:

1. This site will not be re-sampled so the above listed numbers are final.

2. This site has considerable heavy truck traffic on the property. Because of this the owner is concerned about placement of SVE/AS wells. Please contact him to consider the issues he has with lot grading, well placement etc. The owner in the past has been very flexible.

3. This site is not a candidate for overexcvation.

4. The owner would like the islands and lights left in place as the are functional.

5. The owner would like a call before the site is visited by a prospective contractor. I have posted additional phone numbers above to aid in contacting the owner.
Site Questions and Answers: